SPAN-P10R-G18M-PNLK-PNV& (8035533) pressure sensor

OT-FESTO070410

Exemplary representation: SPAN-P10R-G18M-PNLK-PNVBA-L1 (8035533)   &   SPAN-P10R-G18M-PN-PN-L1 (8035544)   &   SPAN-B2R-G18M-PN-PN-L1 (8035545)  & ...
pcs
{{ $t('shop.display.artikel.hinweis_alternative') }}
{{ $t('shop.display.artikel.eigenschaften_headline') }}
Permission RCM mark,
c UL us - Listed (OL)
CE certificate (see declaration of conformity) acc. to EU-EMV Directive,
acc. to EU-RoHS Directive
KC-mark KC-EMV
Certified awarding point UL E322346
Material information RoHs compliant
Measured parameter Relative pressure
Measurement process Piezoresistive pressure sensor
Druckmessbereich Anfangswert (MPa) [MPa] 0
Pressure measurement range starting value [bar] 0
Druckmessbereich Anfangswert (psi) [psi] 0
Druckmessbereich Endwert (MPa) [MPa] 1,0
Pressure measurement range end value [bar] 10
Druckmessbereich Endwert (psi) [psi] 145,0
Overload range [bar] 15
Overload pressure [MPa] 1,5
Überlastdruck (psi) [psi] 217,5
Operating medium Compressed air to ISO 8573-1:2010 [7:4:4],
Inert gases
Information about operating and control medium Oiled operation possible
Medium temperature [°C] 0 to 50
ambient temperature [°C] 0 to 50
Accuracy FS [%FS] 1,5
Repeatability in ± %FS [%FS] 0,3
Temperature coefficient in ± %FS/K [%FS/K] 0,05
Control output 2 x PNP or 2 x NPN switchable
Switch function Window comparator,
Threshold comparator,
Auto difference monitoring
Switching element function Opener/closer switchable
Max. output current [mA] 100
Analogue output 0 - 10 V,
4 - 20 mA,
1 - 5 V
Max. load resistance current output [Ohm] 500
Min. load resistance voltage output [kOhm] 20
Short circuit resistance yes
Report IO-Link
IO-Link, report Device V 1.1
IO-Link, profile Smart sensor profile
IO-Link, function classes Teach channel,
Diagnosis,
Identification,
Binary data channel (BDC),
Process data variables (PDV)
IO-Link, communication mode COM2 (38.4 kBaud)
IO-Link, SIO mode support yes
IO-Link, port type A
IO-Link, process data width OUT 0 Bytes
IO-Link, process data width IN 2 Bytes
IO-Link, process data contents IN 14 bit PDV (pressure measurement),
2 bit BDC (pressure monitoring)
IO-Link, minimum cycle time 3 ms
IO-Link, data memory needed [Byte] 500
Operating voltage range DC [V] 15 to 30
Reverse polarity protection for all electrical connections
Electrical connection 1, connection type Plug
Electrical connection 1, connection technology Wiring diagram L1J
Electrical connection 1, number of pins / wires 4
Fastening type Front panel integration,
With Wall / flat holder,
With thread
installation position arbitrary
Pneumatic connection Male thread G1/8,
female thread M5
Product weight [g] 46
Housing material PA reinforced
From medium contacting materials FPM,
NBR,
PA-verstärkt,
Messing, vernickelt
Display type Illuminating LCD
Presentable unit(s) MPa,
bar,
inchH2O,
inchHg,
kPa,
kgf/cm²,
mbar,
mmHg,
psi
Setting options IO-Link,
Teach-In,
über Display und Tasten
Tamper-proof fuse IO-Link,
PIN code
Settings range threshold value [%] 0 to 100
Settings range hysteresis [%] 0 to 90
Protection category IP40
Corrosion resistant class KBK 2 - moderate corrosion stress
OT-FESTO070410
{{ $t('shop.all.gewicht') }} 46 g / pcs
{{ $t('shop.display.artikel.zollwarennummer') }} 90262020
{{ $t('shop.all.hersteller') }} Festo
{{ $t('shop.all.dokumente') }}

 
{{ $t('shop.all.unverbindliche_richtwerte') }}

Accessories

{{ $t('shop.all.spaetbestellservice') }}
{{ countdownAsString }} {{ $t('shop.modules.navi.fruehbucher-spaetbestellhinweis.noch') }}
{{ $t('shop.modules.navi.fruehbucher-spaetbestellhinweis.noch') }} {{ countdownAsString }}

{{ $t('shop.all.spaetbestellservice.hinweis') }}

{{ $t('shop.all.wochenendversand') }}
{{ $t('shop.modules.navi.fruehbucher-spaetbestellhinweis.noch') }} {{ countdownAsString }}

{{ $t('shop.all.wochenendversand.hinweis') }}

An error has occurred!

An error has occurred, please reload this page and try again.